"""Modbus Client Common."""
|
|
from __future__ import annotations
|
|
|
|
import struct
|
|
from abc import abstractmethod
|
|
from enum import Enum
|
|
from typing import Generic, Literal, TypeVar, cast
|
|
|
|
import pymodbus.pdu.bit_message as pdu_bit
|
|
import pymodbus.pdu.diag_message as pdu_diag
|
|
import pymodbus.pdu.file_message as pdu_file_msg
|
|
import pymodbus.pdu.mei_message as pdu_mei
|
|
import pymodbus.pdu.other_message as pdu_other_msg
|
|
import pymodbus.pdu.register_message as pdu_reg
|
|
from pymodbus.constants import ModbusStatus
|
|
from pymodbus.exceptions import ModbusException
|
|
from pymodbus.pdu import ModbusPDU
|
|
from pymodbus.utilities import pack_bitstring, unpack_bitstring
|
|
|
|
|
|
T = TypeVar("T", covariant=False)
|
|
|
|
|
|
class ModbusClientMixin(Generic[T]): # pylint: disable=too-many-public-methods
|
|
"""**ModbusClientMixin**.
|
|
|
|
This is an interface class to facilitate the sending requests/receiving responses like read_coils.
|
|
execute() allows to make a call with non-standard or user defined function codes (remember to add a PDU
|
|
in the transport class to interpret the request/response).
|
|
|
|
Simple modbus message call::
|
|
|
|
response = client.read_coils(1, 10)
|
|
# or
|
|
response = await client.read_coils(1, 10)
|
|
|
|
Advanced modbus message call::
|
|
|
|
request = ReadCoilsRequest(1,10)
|
|
response = client.execute(False, request)
|
|
# or
|
|
request = ReadCoilsRequest(1,10)
|
|
response = await client.execute(False, request)
|
|
|
|
.. tip::
|
|
All methods can be used directly (synchronous) or
|
|
with await <method> (asynchronous) depending on the client used.
|
|
"""
|
|
|
|
def __init__(self):
|
|
"""Initialize."""
|
|
|
|
@abstractmethod
|
|
def execute(self, no_response_expected: bool, request: ModbusPDU) -> T:
|
|
"""Execute request."""
|
|
|
|
def read_coils(self, address: int, *, count: int = 1, slave: int = 1, no_response_expected: bool = False) -> T:
|
|
"""Read coils (code 0x01).
|
|
|
|
:param address: Start address to read from
|
|
:param count: (optional) Number of coils to read
|
|
:param slave: (optional) Modbus slave ID
|
|
:param no_response_expected: (optional) The client will not expect a response to the request
|
|
:raises ModbusException:
|
|
|
|
reads from 1 to 2000 contiguous in a remote device (slave).
|
|
|
|
Coils are addressed as 0-N (Note some device manuals uses 1-N, assuming 1==0).
|
|
"""
|
|
return self.execute(no_response_expected, pdu_bit.ReadCoilsRequest(address=address, count=count, dev_id=slave))
|
|
|
|
def read_discrete_inputs(self,
|
|
address: int,
|
|
*,
|
|
count: int = 1,
|
|
slave: int = 1,
|
|
no_response_expected: bool = False) -> T:
|
|
"""Read discrete inputs (code 0x02).
|
|
|
|
:param address: Start address to read from
|
|
:param count: (optional) Number of coils to read
|
|
:param slave: (optional) Modbus slave ID
|
|
:param no_response_expected: (optional) The client will not expect a response to the request
|
|
:raises ModbusException:
|
|
|
|
read from 1 to 2000(0x7d0) discrete inputs (bits) in a remote device.
|
|
|
|
Discrete Inputs are addressed as 0-N (Note some device manuals uses 1-N, assuming 1==0).
|
|
"""
|
|
pdu = pdu_bit.ReadDiscreteInputsRequest(address=address, count=count, dev_id=slave)
|
|
return self.execute(no_response_expected, pdu)
|
|
|
|
def read_holding_registers(self,
|
|
address: int,
|
|
*,
|
|
count: int = 1,
|
|
slave: int = 1,
|
|
no_response_expected: bool = False) -> T:
|
|
"""Read holding registers (code 0x03).
|
|
|
|
:param address: Start address to read from
|
|
:param count: (optional) Number of registers to read
|
|
:param slave: (optional) Modbus slave ID
|
|
:param no_response_expected: (optional) The client will not expect a response to the request
|
|
:raises ModbusException:
|
|
|
|
This function is used to read the contents of a contiguous block
|
|
of holding registers in a remote device. The Request specifies the
|
|
starting register address and the number of registers.
|
|
|
|
Registers are addressed starting at zero.
|
|
Therefore devices that specify 1-16 are addressed as 0-15.
|
|
"""
|
|
return self.execute(no_response_expected, pdu_reg.ReadHoldingRegistersRequest(address=address, count=count, dev_id=slave))
|
|
|
|
def read_input_registers(self,
|
|
address: int,
|
|
*,
|
|
count: int = 1,
|
|
slave: int = 1,
|
|
no_response_expected: bool = False) -> T:
|
|
"""Read input registers (code 0x04).
|
|
|
|
:param address: Start address to read from
|
|
:param count: (optional) Number of coils to read
|
|
:param slave: (optional) Modbus slave ID
|
|
:param no_response_expected: (optional) The client will not expect a response to the request
|
|
:raises ModbusException:
|
|
|
|
This function is used to read from 1 to approx. 125 contiguous
|
|
input registers in a remote device. The Request specifies the
|
|
starting register address and the number of registers.
|
|
|
|
Registers are addressed starting at zero.
|
|
Therefore devices that specify 1-16 are addressed as 0-15.
|
|
"""
|
|
return self.execute(no_response_expected, pdu_reg.ReadInputRegistersRequest(address=address, count=count, dev_id=slave))
|
|
|
|
def write_coil(self, address: int, value: bool, *, slave: int = 1, no_response_expected: bool = False) -> T:
|
|
"""Write single coil (code 0x05).
|
|
|
|
:param address: Address to write to
|
|
:param value: Boolean to write
|
|
:param slave: (optional) Modbus slave ID
|
|
:param no_response_expected: (optional) The client will not expect a response to the request
|
|
:raises ModbusException:
|
|
|
|
write ON/OFF to a single coil in a remote device.
|
|
|
|
Coils are addressed as 0-N (Note some device manuals uses 1-N, assuming 1==0).
|
|
"""
|
|
pdu = pdu_bit.WriteSingleCoilRequest(address=address, bits=[value], dev_id=slave)
|
|
return self.execute(no_response_expected, pdu)
|
|
|
|
def write_register(self, address: int, value: int, *, slave: int = 1, no_response_expected: bool = False) -> T:
|
|
"""Write register (code 0x06).
|
|
|
|
:param address: Address to write to
|
|
:param value: Value to write
|
|
:param slave: (optional) Modbus slave ID
|
|
:param no_response_expected: (optional) The client will not expect a response to the request
|
|
:raises ModbusException:
|
|
|
|
This function is used to write a single holding register in a remote device.
|
|
|
|
The Request specifies the address of the register to be written.
|
|
|
|
Registers are addressed starting at zero. Therefore register
|
|
numbered 1 is addressed as 0.
|
|
"""
|
|
return self.execute(no_response_expected, pdu_reg.WriteSingleRegisterRequest(address=address, registers=[value], dev_id=slave))
|
|
|
|
def read_exception_status(self, *, slave: int = 1, no_response_expected: bool = False) -> T:
|
|
"""Read Exception Status (code 0x07).
|
|
|
|
:param slave: (optional) Modbus slave ID
|
|
:param no_response_expected: (optional) The client will not expect a response to the request
|
|
:raises ModbusException:
|
|
|
|
This function is used to read the contents of eight Exception Status outputs in a remote device.
|
|
|
|
The function provides a simple method for
|
|
accessing this information, because the Exception Output references are
|
|
known (no output reference is needed in the function).
|
|
"""
|
|
return self.execute(no_response_expected, pdu_other_msg.ReadExceptionStatusRequest(dev_id=slave))
|
|
|
|
def diag_query_data(self, msg: bytes, *, slave: int = 1, no_response_expected: bool = False) -> T:
|
|
"""Diagnose query data (code 0x08 sub 0x00).
|
|
|
|
:param msg: Message to be returned
|
|
:param slave: (optional) Modbus slave ID
|
|
:param no_response_expected: (optional) The client will not expect a response to the request
|
|
:raises ModbusException:
|
|
|
|
The data passed in the request data field is to be returned (looped back)
|
|
in the response. The entire response message should be identical to the
|
|
request.
|
|
"""
|
|
return self.execute(no_response_expected, pdu_diag.ReturnQueryDataRequest(msg, dev_id=slave))
|
|
|
|
def diag_restart_communication(self, toggle: bool, *, slave: int = 1, no_response_expected: bool = False) -> T:
|
|
"""Diagnose restart communication (code 0x08 sub 0x01).
|
|
|
|
:param toggle: True if toggled.
|
|
:param slave: (optional) Modbus slave ID
|
|
:param no_response_expected: (optional) The client will not expect a response to the request
|
|
:raises ModbusException:
|
|
|
|
The remote device serial line port must be initialized and restarted, and
|
|
all of its communications event counters are cleared. If the port is
|
|
currently in Listen Only Mode, no response is returned. This function is
|
|
the only one that brings the port out of Listen Only Mode. If the port is
|
|
not currently in Listen Only Mode, a normal response is returned. This
|
|
occurs before the restart is update_datastored.
|
|
"""
|
|
msg = ModbusStatus.ON if toggle else ModbusStatus.OFF
|
|
return self.execute(no_response_expected, pdu_diag.RestartCommunicationsOptionRequest(message=msg, dev_id=slave))
|
|
|
|
def diag_read_diagnostic_register(self, *, slave: int = 1, no_response_expected: bool = False) -> T:
|
|
"""Diagnose read diagnostic register (code 0x08 sub 0x02).
|
|
|
|
:param slave: (optional) Modbus slave ID
|
|
:param no_response_expected: (optional) The client will not expect a response to the request
|
|
:raises ModbusException:
|
|
|
|
The contents of the remote device's 16-bit diagnostic register are returned in the response.
|
|
"""
|
|
return self.execute(no_response_expected, pdu_diag.ReturnDiagnosticRegisterRequest(dev_id=slave))
|
|
|
|
def diag_change_ascii_input_delimeter(self, *, delimiter: int = 0x0a, slave: int = 1, no_response_expected: bool = False) -> T:
|
|
"""Diagnose change ASCII input delimiter (code 0x08 sub 0x03).
|
|
|
|
:param delimiter: char to replace LF
|
|
:param slave: (optional) Modbus slave ID
|
|
:param no_response_expected: (optional) The client will not expect a response to the request
|
|
:raises ModbusException:
|
|
|
|
The character passed in the request becomes the end of
|
|
message delimiter for future messages (replacing the default LF
|
|
character). This function is useful in cases of a Line Feed is not
|
|
required at the end of ASCII messages.
|
|
"""
|
|
return self.execute(no_response_expected, pdu_diag.ChangeAsciiInputDelimiterRequest(message=delimiter, dev_id=slave))
|
|
|
|
def diag_force_listen_only(self, *, slave: int = 1, no_response_expected: bool = False) -> T:
|
|
"""Diagnose force listen only (code 0x08 sub 0x04).
|
|
|
|
:param slave: (optional) Modbus slave ID
|
|
:param no_response_expected: (optional) The client will not expect a response to the request
|
|
:raises ModbusException:
|
|
|
|
Forces the addressed remote device to its Listen Only Mode for MODBUS communications.
|
|
|
|
This isolates it from the other devices on the network,
|
|
allowing them to continue communicating without interruption from the
|
|
addressed remote device. No response is returned.
|
|
"""
|
|
return self.execute(no_response_expected, pdu_diag.ForceListenOnlyModeRequest(dev_id=slave))
|
|
|
|
def diag_clear_counters(self, *, slave: int = 1, no_response_expected: bool = False) -> T:
|
|
"""Diagnose clear counters (code 0x08 sub 0x0A).
|
|
|
|
:param slave: (optional) Modbus slave ID
|
|
:param no_response_expected: (optional) The client will not expect a response to the request
|
|
:raises ModbusException:
|
|
|
|
Clear ll counters and the diagnostic register. Also, counters are cleared upon power-up
|
|
"""
|
|
return self.execute(no_response_expected, pdu_diag.ClearCountersRequest(dev_id=slave))
|
|
|
|
def diag_read_bus_message_count(self, *, slave: int = 1, no_response_expected: bool = False) -> T:
|
|
"""Diagnose read bus message count (code 0x08 sub 0x0B).
|
|
|
|
:param slave: (optional) Modbus slave ID
|
|
:param no_response_expected: (optional) The client will not expect a response to the request
|
|
:raises ModbusException:
|
|
|
|
The response data field returns the quantity of messages that the
|
|
remote device has detected on the communications systems since its last
|
|
restart, clear counters operation, or power-up
|
|
"""
|
|
return self.execute(no_response_expected, pdu_diag.ReturnBusMessageCountRequest(dev_id=slave))
|
|
|
|
def diag_read_bus_comm_error_count(self, *, slave: int = 1, no_response_expected: bool = False) -> T:
|
|
"""Diagnose read Bus Communication Error Count (code 0x08 sub 0x0C).
|
|
|
|
:param slave: (optional) Modbus slave ID
|
|
:param no_response_expected: (optional) The client will not expect a response to the request
|
|
:raises ModbusException:
|
|
|
|
The response data field returns the quantity of CRC errors encountered
|
|
by the remote device since its last restart, clear counter operation, or
|
|
power-up
|
|
"""
|
|
return self.execute(no_response_expected, pdu_diag.ReturnBusCommunicationErrorCountRequest(dev_id=slave))
|
|
|
|
def diag_read_bus_exception_error_count(self, *, slave: int = 1, no_response_expected: bool = False) -> T:
|
|
"""Diagnose read Bus Exception Error Count (code 0x08 sub 0x0D).
|
|
|
|
:param slave: (optional) Modbus slave ID
|
|
:param no_response_expected: (optional) The client will not expect a response to the request
|
|
:raises ModbusException:
|
|
|
|
The response data field returns the quantity of modbus exception
|
|
responses returned by the remote device since its last restart,
|
|
clear counters operation, or power-up
|
|
"""
|
|
return self.execute(no_response_expected, pdu_diag.ReturnBusExceptionErrorCountRequest(dev_id=slave))
|
|
|
|
def diag_read_slave_message_count(self, *, slave: int = 1, no_response_expected: bool = False) -> T:
|
|
"""Diagnose read Slave Message Count (code 0x08 sub 0x0E).
|
|
|
|
:param slave: (optional) Modbus slave ID
|
|
:param no_response_expected: (optional) The client will not expect a response to the request
|
|
:raises ModbusException:
|
|
|
|
The response data field returns the quantity of messages addressed to the
|
|
remote device, that the remote device has processed since
|
|
its last restart, clear counters operation, or power-up
|
|
"""
|
|
return self.execute(no_response_expected, pdu_diag.ReturnSlaveMessageCountRequest(dev_id=slave))
|
|
|
|
def diag_read_slave_no_response_count(self, *, slave: int = 1, no_response_expected: bool = False) -> T:
|
|
"""Diagnose read Slave No Response Count (code 0x08 sub 0x0F).
|
|
|
|
:param slave: (optional) Modbus slave ID
|
|
:param no_response_expected: (optional) The client will not expect a response to the request
|
|
:raises ModbusException:
|
|
|
|
The response data field returns the quantity of messages addressed to the
|
|
remote device, that the remote device has processed since
|
|
its last restart, clear counters operation, or power-up.
|
|
"""
|
|
return self.execute(no_response_expected, pdu_diag.ReturnSlaveNoResponseCountRequest(dev_id=slave))
|
|
|
|
def diag_read_slave_nak_count(self, *, slave: int = 1, no_response_expected: bool = False) -> T:
|
|
"""Diagnose read Slave NAK Count (code 0x08 sub 0x10).
|
|
|
|
:param slave: (optional) Modbus slave ID
|
|
:param no_response_expected: (optional) The client will not expect a response to the request
|
|
:raises ModbusException:
|
|
|
|
The response data field returns the quantity of messages addressed to the
|
|
remote device for which it returned a Negative ACKNOWLEDGE (NAK) exception
|
|
response, since its last restart, clear counters operation, or power-up.
|
|
Exception responses are described and listed in section 7 .
|
|
"""
|
|
return self.execute(no_response_expected, pdu_diag.ReturnSlaveNAKCountRequest(dev_id=slave))
|
|
|
|
def diag_read_slave_busy_count(self, *, slave: int = 1, no_response_expected: bool = False) -> T:
|
|
"""Diagnose read Slave Busy Count (code 0x08 sub 0x11).
|
|
|
|
:param slave: (optional) Modbus slave ID
|
|
:param no_response_expected: (optional) The client will not expect a response to the request
|
|
:raises ModbusException:
|
|
|
|
The response data field returns the quantity of messages addressed to the
|
|
remote device for which it returned a Slave Device Busy exception response,
|
|
since its last restart, clear counters operation, or power-up.
|
|
"""
|
|
return self.execute(no_response_expected, pdu_diag.ReturnSlaveBusyCountRequest(dev_id=slave))
|
|
|
|
def diag_read_bus_char_overrun_count(self, *, slave: int = 1, no_response_expected: bool = False) -> T:
|
|
"""Diagnose read Bus Character Overrun Count (code 0x08 sub 0x12).
|
|
|
|
:param slave: (optional) Modbus slave ID
|
|
:param no_response_expected: (optional) The client will not expect a response to the request
|
|
:raises ModbusException:
|
|
|
|
The response data field returns the quantity of messages addressed to the
|
|
remote device that it could not handle due to a character overrun condition,
|
|
since its last restart, clear counters operation, or power-up. A character
|
|
overrun is caused by data characters arriving at the port faster than they
|
|
can be stored, or by the loss of a character due to a hardware malfunction.
|
|
"""
|
|
return self.execute(no_response_expected, pdu_diag.ReturnSlaveBusCharacterOverrunCountRequest(dev_id=slave))
|
|
|
|
def diag_read_iop_overrun_count(self, *, slave: int = 1, no_response_expected: bool = False) -> T:
|
|
"""Diagnose read Iop overrun count (code 0x08 sub 0x13).
|
|
|
|
:param slave: (optional) Modbus slave ID
|
|
:param no_response_expected: (optional) The client will not expect a response to the request
|
|
:raises ModbusException:
|
|
|
|
An IOP overrun is caused by data characters arriving at the port
|
|
faster than they can be stored, or by the loss of a character due
|
|
to a hardware malfunction. This function is specific to the 884.
|
|
"""
|
|
return self.execute(no_response_expected, pdu_diag.ReturnIopOverrunCountRequest(dev_id=slave))
|
|
|
|
def diag_clear_overrun_counter(self, *, slave: int = 1, no_response_expected: bool = False) -> T:
|
|
"""Diagnose Clear Overrun Counter and Flag (code 0x08 sub 0x14).
|
|
|
|
:param slave: (optional) Modbus slave ID
|
|
:param no_response_expected: (optional) The client will not expect a response to the request
|
|
:raises ModbusException:
|
|
|
|
An error flag should be cleared, but nothing else in the
|
|
specification mentions is, so it is ignored.
|
|
"""
|
|
return self.execute(no_response_expected, pdu_diag.ClearOverrunCountRequest(dev_id=slave))
|
|
|
|
def diag_getclear_modbus_response(self, *, data: int = 0, slave: int = 1, no_response_expected: bool = False) -> T:
|
|
"""Diagnose Get/Clear modbus plus (code 0x08 sub 0x15).
|
|
|
|
:param data: "Get Statistics" or "Clear Statistics"
|
|
:param slave: (optional) Modbus slave ID
|
|
:param no_response_expected: (optional) The client will not expect a response to the request
|
|
:raises ModbusException:
|
|
|
|
In addition to the Function code (08) and Subfunction code
|
|
(00 15 hex) in the query, a two-byte Operation field is used
|
|
to specify either a "Get Statistics" or a "Clear Statistics"
|
|
operation. The two operations are exclusive - the "Get"
|
|
operation cannot clear the statistics, and the "Clear"
|
|
operation does not return statistics prior to clearing
|
|
them. Statistics are also cleared on power-up of the slave
|
|
device.
|
|
"""
|
|
return self.execute(no_response_expected, pdu_diag.GetClearModbusPlusRequest(message=data, dev_id=slave))
|
|
|
|
def diag_get_comm_event_counter(self, *, slave: int = 1, no_response_expected: bool = False) -> T:
|
|
"""Diagnose get event counter (code 0x0B).
|
|
|
|
:param slave: (optional) Modbus slave ID
|
|
:param no_response_expected: (optional) The client will not expect a response to the request
|
|
:raises ModbusException:
|
|
|
|
This function is used to get a status word and an event count from the remote device.
|
|
|
|
By fetching the current count before and after a series of messages, a
|
|
client can determine whether the messages were handled normally by the
|
|
remote device.
|
|
|
|
The device's event counter is incremented once for each successful
|
|
message completion. It is not incremented for exception responses,
|
|
poll commands, or fetch event counter commands.
|
|
|
|
The event counter can be reset by means of the Diagnostics function
|
|
Restart Communications or Clear Counters and Diagnostic Register.
|
|
"""
|
|
return self.execute(no_response_expected, pdu_other_msg.GetCommEventCounterRequest(dev_id=slave))
|
|
|
|
def diag_get_comm_event_log(self, *, slave: int = 1, no_response_expected: bool = False) -> T:
|
|
"""Diagnose get event counter (code 0x0C).
|
|
|
|
:param slave: (optional) Modbus slave ID
|
|
:param no_response_expected: (optional) The client will not expect a response to the request
|
|
:raises ModbusException:
|
|
|
|
This function is used to get a status word.
|
|
|
|
Event count, message count, and a field of event bytes from the remote device.
|
|
|
|
The status word and event counts are identical to that returned by
|
|
the Get Communications Event Counter function.
|
|
|
|
The message counter contains the quantity of messages processed by the
|
|
remote device since its last restart, clear counters operation, or
|
|
power-up. This count is identical to that returned by the Diagnostic
|
|
function Return Bus Message Count.
|
|
|
|
The event bytes field contains 0-64 bytes, with each byte corresponding
|
|
to the status of one MODBUS send or receive operation for the remote
|
|
device. The remote device enters the events into the field in
|
|
chronological order. Byte 0 is the most recent event. Each new byte
|
|
flushes the oldest byte from the field.
|
|
"""
|
|
return self.execute(no_response_expected, pdu_other_msg.GetCommEventLogRequest(dev_id=slave))
|
|
|
|
def write_coils(
|
|
self,
|
|
address: int,
|
|
values: list[bool],
|
|
*,
|
|
slave: int = 1,
|
|
no_response_expected: bool = False
|
|
) -> T:
|
|
"""Write coils (code 0x0F).
|
|
|
|
:param address: Start address to write to
|
|
:param values: List of booleans to write, or a single boolean to write
|
|
:param slave: (optional) Modbus slave ID
|
|
:param no_response_expected: (optional) The client will not expect a response to the request
|
|
:raises ModbusException:
|
|
|
|
write ON/OFF to multiple coils in a remote device.
|
|
|
|
Coils are addressed as 0-N (Note some device manuals uses 1-N, assuming 1==0).
|
|
"""
|
|
pdu = pdu_bit.WriteMultipleCoilsRequest(address=address, bits=values, dev_id=slave)
|
|
return self.execute(no_response_expected, pdu)
|
|
|
|
def write_registers(
|
|
self,
|
|
address: int,
|
|
values: list[int],
|
|
*,
|
|
slave: int = 1,
|
|
no_response_expected: bool = False
|
|
) -> T:
|
|
"""Write registers (code 0x10).
|
|
|
|
:param address: Start address to write to
|
|
:param values: List of values to write
|
|
:param slave: (optional) Modbus slave ID
|
|
:param no_response_expected: (optional) The client will not expect a response to the request
|
|
:raises ModbusException:
|
|
|
|
This function is used to write a block of contiguous registers
|
|
(1 to approx. 120 registers) in a remote device.
|
|
"""
|
|
return self.execute(no_response_expected, pdu_reg.WriteMultipleRegistersRequest(address=address, registers=values,dev_id=slave))
|
|
|
|
def report_slave_id(self, *, slave: int = 1, no_response_expected: bool = False) -> T:
|
|
"""Report slave ID (code 0x11).
|
|
|
|
:param slave: (optional) Modbus slave ID
|
|
:param no_response_expected: (optional) The client will not expect a response to the request
|
|
:raises ModbusException:
|
|
|
|
This function is used to read the description of the type, the current status
|
|
and other information specific to a remote device.
|
|
"""
|
|
return self.execute(no_response_expected, pdu_other_msg.ReportSlaveIdRequest(dev_id=slave))
|
|
|
|
def read_file_record(self, records: list[pdu_file_msg.FileRecord], *, slave: int = 1, no_response_expected: bool = False) -> T:
|
|
"""Read file record (code 0x14).
|
|
|
|
:param records: List of FileRecord (Reference type, File number, Record Number)
|
|
:param slave: device id
|
|
:param no_response_expected: (optional) The client will not expect a response to the request
|
|
:raises ModbusException:
|
|
|
|
This function is used to perform a file record read. All request
|
|
data lengths are provided in terms of number of bytes and all record
|
|
lengths are provided in terms of registers.
|
|
|
|
A file is an organization of records. Each file contains 10000 records,
|
|
addressed 0000 to 9999 decimal or 0x0000 to 0x270f. For example, record
|
|
12 is addressed as 12. The function can read multiple groups of
|
|
references. The groups can be separating (non-contiguous), but the
|
|
references within each group must be sequential. Each group is defined
|
|
in a separate "sub-request" field that contains seven bytes::
|
|
|
|
The reference type: 1 byte
|
|
The file number: 2 bytes
|
|
The starting record number within the file: 2 bytes
|
|
The length of the record to be read: 2 bytes
|
|
|
|
The quantity of registers to be read, combined with all other fields
|
|
in the expected response, must not exceed the allowable length of the
|
|
MODBUS PDU: 235 bytes.
|
|
"""
|
|
return self.execute(no_response_expected, pdu_file_msg.ReadFileRecordRequest(records, dev_id=slave))
|
|
|
|
def write_file_record(self, records: list[pdu_file_msg.FileRecord], *, slave: int = 1, no_response_expected: bool = False) -> T:
|
|
"""Write file record (code 0x15).
|
|
|
|
:param records: List of File_record (Reference type, File number, Record Number, Record Length, Record Data)
|
|
:param slave: (optional) Device id
|
|
:param no_response_expected: (optional) The client will not expect a response to the request
|
|
:raises ModbusException:
|
|
|
|
This function is used to perform a file record write. All
|
|
request data lengths are provided in terms of number of bytes
|
|
and all record lengths are provided in terms of the number of 16
|
|
bit words.
|
|
"""
|
|
return self.execute(no_response_expected, pdu_file_msg.WriteFileRecordRequest(records=records, dev_id=slave))
|
|
|
|
def mask_write_register(
|
|
self,
|
|
*,
|
|
address: int = 0x0000,
|
|
and_mask: int = 0xFFFF,
|
|
or_mask: int = 0x0000,
|
|
slave: int = 1,
|
|
no_response_expected: bool = False
|
|
) -> T:
|
|
"""Mask write register (code 0x16).
|
|
|
|
:param address: The mask pointer address (0x0000 to 0xffff)
|
|
:param and_mask: The and bitmask to apply to the register address
|
|
:param or_mask: The or bitmask to apply to the register address
|
|
:param slave: (optional) device id
|
|
:param no_response_expected: (optional) The client will not expect a response to the request
|
|
:raises ModbusException:
|
|
|
|
This function is used to modify the contents of a specified holding register
|
|
using a combination of an AND mask, an OR mask, and the register's current contents.
|
|
|
|
The function can be used to set or clear individual bits in the register.
|
|
"""
|
|
return self.execute(no_response_expected, pdu_reg.MaskWriteRegisterRequest(address=address, and_mask=and_mask, or_mask=or_mask, dev_id=slave))
|
|
|
|
def readwrite_registers(
|
|
self,
|
|
*,
|
|
read_address: int = 0,
|
|
read_count: int = 0,
|
|
write_address: int = 0,
|
|
address: int | None = None,
|
|
values: list[int] | None = None,
|
|
slave: int = 1,
|
|
no_response_expected: bool = False
|
|
) -> T:
|
|
"""Read/Write registers (code 0x17).
|
|
|
|
:param read_address: The address to start reading from
|
|
:param read_count: The number of registers to read from address
|
|
:param write_address: The address to start writing to
|
|
:param address: (optional) use as read/write address
|
|
:param values: List of values to write, or a single value to write
|
|
:param slave: (optional) Modbus slave ID
|
|
:param no_response_expected: (optional) The client will not expect a response to the request
|
|
:raises ModbusException:
|
|
|
|
This function performs a combination of one read operation and one
|
|
write operation in a single MODBUS transaction. The write
|
|
operation is performed before the read.
|
|
|
|
Holding registers are addressed starting at zero. Therefore holding
|
|
registers 1-16 are addressed in the PDU as 0-15.
|
|
"""
|
|
if not values:
|
|
values = []
|
|
if address:
|
|
read_address = address
|
|
write_address = address
|
|
return self.execute(no_response_expected, pdu_reg.ReadWriteMultipleRegistersRequest( read_address=read_address, read_count=read_count, write_address=write_address, write_registers=values,dev_id=slave))
|
|
|
|
def read_fifo_queue(self, *, address: int = 0x0000, slave: int = 1, no_response_expected: bool = False) -> T:
|
|
"""Read FIFO queue (code 0x18).
|
|
|
|
:param address: The address to start reading from
|
|
:param slave: (optional) device id
|
|
:param no_response_expected: (optional) The client will not expect a response to the request
|
|
:raises ModbusException:
|
|
|
|
This function allows to read the contents of a First-In-First-Out
|
|
(FIFO) queue of register in a remote device. The function returns a
|
|
count of the registers in the queue, followed by the queued data.
|
|
Up to 32 registers can be read: the count, plus up to 31 queued data
|
|
registers.
|
|
|
|
The queue count register is returned first, followed by the queued data
|
|
registers. The function reads the queue contents, but does not clear
|
|
them.
|
|
"""
|
|
return self.execute(no_response_expected, pdu_file_msg.ReadFifoQueueRequest(address, dev_id=slave))
|
|
|
|
# code 0x2B sub 0x0D: CANopen General Reference Request and Response, NOT IMPLEMENTED
|
|
|
|
def read_device_information(self, *, read_code: int | None = None,
|
|
object_id: int = 0x00,
|
|
slave: int = 1,
|
|
no_response_expected: bool = False) -> T:
|
|
"""Read FIFO queue (code 0x2B sub 0x0E).
|
|
|
|
:param read_code: The device information read code
|
|
:param object_id: The object to read from
|
|
:param slave: (optional) Device id
|
|
:param no_response_expected: (optional) The client will not expect a response to the request
|
|
:raises ModbusException:
|
|
|
|
This function allows reading the identification and additional
|
|
information relative to the physical and functional description of a
|
|
remote device, only.
|
|
|
|
The Read Device Identification interface is modeled as an address space
|
|
composed of a set of addressable data elements. The data elements are
|
|
called objects and an object Id identifies them.
|
|
"""
|
|
return self.execute(no_response_expected, pdu_mei.ReadDeviceInformationRequest(read_code, object_id, dev_id=slave))
|
|
|
|
# ------------------
|
|
# Converter methods
|
|
# ------------------
|
|
|
|
class DATATYPE(Enum):
|
|
"""Datatype enum (name and internal data), used for convert_* calls."""
|
|
|
|
INT16 = ("h", 1)
|
|
UINT16 = ("H", 1)
|
|
INT32 = ("i", 2)
|
|
UINT32 = ("I", 2)
|
|
INT64 = ("q", 4)
|
|
UINT64 = ("Q", 4)
|
|
FLOAT32 = ("f", 2)
|
|
FLOAT64 = ("d", 4)
|
|
STRING = ("s", 0)
|
|
BITS = ("bits", 0)
|
|
|
|
@classmethod
|
|
def convert_from_registers(
|
|
cls, registers: list[int], data_type: DATATYPE, word_order: Literal["big", "little"] = "big", string_encoding: str = "utf-8"
|
|
) -> int | float | str | list[bool] | list[int] | list[float]:
|
|
"""Convert registers to int/float/str.
|
|
|
|
:param registers: list of registers received from e.g. read_holding_registers()
|
|
:param data_type: data type to convert to
|
|
:param word_order: "big"/"little" order of words/registers
|
|
:param string_encoding: The encoding with which to decode the bytearray, only used when data_type=DATATYPE.STRING
|
|
:returns: scalar or array of "data_type"
|
|
:raises ModbusException: when size of registers is not a multiple of data_type
|
|
:raises ParameterException: when the specified string encoding is not supported
|
|
"""
|
|
if not (data_len := data_type.value[1]):
|
|
byte_list = bytearray()
|
|
if word_order == "little":
|
|
registers.reverse()
|
|
for x in registers:
|
|
byte_list.extend(int.to_bytes(x, 2, "big"))
|
|
if data_type == cls.DATATYPE.STRING:
|
|
trailing_nulls_begin = len(byte_list)
|
|
while trailing_nulls_begin > 0 and not byte_list[trailing_nulls_begin - 1]:
|
|
trailing_nulls_begin -= 1
|
|
byte_list = byte_list[:trailing_nulls_begin]
|
|
return byte_list.decode(string_encoding)
|
|
return unpack_bitstring(byte_list)
|
|
if (reg_len := len(registers)) % data_len:
|
|
raise ModbusException(
|
|
f"Registers illegal size ({len(registers)}) expected multiple of {data_len}!"
|
|
)
|
|
|
|
result = []
|
|
for i in range(0, reg_len, data_len):
|
|
regs = registers[i:i+data_len]
|
|
if word_order == "little":
|
|
regs.reverse()
|
|
byte_list = bytearray()
|
|
for x in regs:
|
|
byte_list.extend(int.to_bytes(x, 2, "big"))
|
|
result.append(struct.unpack(f">{data_type.value[0]}", byte_list)[0])
|
|
return result if len(result) != 1 else result[0]
|
|
|
|
@classmethod
|
|
def convert_to_registers(
|
|
cls, value: int | float | str | list[bool] | list[int] | list[float], data_type: DATATYPE, word_order: Literal["big", "little"] = "big", string_encoding: str = "utf-8"
|
|
) -> list[int]:
|
|
"""Convert int/float/str to registers (16/32/64 bit).
|
|
|
|
:param value: value to be converted
|
|
:param data_type: data type to convert from
|
|
:param word_order: "big"/"little" order of words/registers
|
|
:param string_encoding: The encoding with which to encode the bytearray, only used when data_type=DATATYPE.STRING
|
|
:returns: List of registers, can be used directly in e.g. write_registers()
|
|
:raises TypeError: when there is a mismatch between data_type and value
|
|
:raises ParameterException: when the specified string encoding is not supported
|
|
"""
|
|
if data_type == cls.DATATYPE.BITS:
|
|
if not isinstance(value, list):
|
|
raise TypeError(f"Value should be list of bool but is {type(value)}.")
|
|
if (missing := len(value) % 16):
|
|
value = value + [False] * (16 - missing)
|
|
byte_list = pack_bitstring(cast(list[bool], value))
|
|
elif data_type == cls.DATATYPE.STRING:
|
|
if not isinstance(value, str):
|
|
raise TypeError(f"Value should be string but is {type(value)}.")
|
|
byte_list = value.encode(string_encoding)
|
|
if len(byte_list) % 2:
|
|
byte_list += b"\x00"
|
|
else:
|
|
if not isinstance(value, list):
|
|
value = cast(list[int], [value])
|
|
byte_list = bytearray()
|
|
for v in value:
|
|
byte_list.extend(struct.pack(f">{data_type.value[0]}", v))
|
|
regs = [
|
|
int.from_bytes(byte_list[x : x + 2], "big")
|
|
for x in range(0, len(byte_list), 2)
|
|
]
|
|
if word_order == "little":
|
|
regs.reverse()
|
|
return regs
|