# Tight X_entry heatup reach: T_c in [285, 291] (6 K vs 14 K baseline). # Produces the clean "all 6 inv1_holds halfspaces discharged at T=300s" # result from 2026-04-20 overnight session. name = "tight" description = "Narrow X_entry on T_c/T_f/T_cold; n in [1e-3, 2e-3]" use_predicates_entry = false [entry] n_range = [1.0e-3, 2.0e-3] T_f_range_C = [285.0, 291.0] T_c_range_C = [285.0, 291.0] T_cold_range_C = [278.0, 285.0] [tmjets] orderT = 4 orderQ = 2 abstol = 1e-9 maxsteps = 100000 [probes] horizons_seconds = [60.0, 300.0] [output] save_per_step = true result_file = "reach_heatup_pj_tight.mat"